Polling Software Advancements and Corrections by Build Number
V7 Build 225 (7.3.1.225) – April 1, 2011 - Full Release Version
General Changes:
- Import/Export -> fixed access violation when exporting a custom consolidation report.
- Keyboards -> Mass plu update now changes the descriptors as the user clicks on items
- Machine Area -> set up to save and restore grid settings
- Report Options -> Fixed problem with Casio TCP/IP report options disabling consolidation options. This has been corrected.
- Base PLU -> Added a check in the BuildSubcatList routine for a blank dept. number which caused an a/v when importing PLUs into an empty table
- AllPolls Area -> set up to save and restore grid settings
- PLU Maintenance -> Fixed mass update to only work for AIMsiSubcategory when the PLU table is filtered.
- Validation -> Fixed a range check error when attempting to validate tables larger then 2 GB.
- XLS ->Templates with Multiple Tabs now supported
- AIMsi Interface -> Added ability to refresh the Category Map table when category and sub category descriptions have changed.
- AIMsi Interface -> fixed a problem getting the correct General Function program for the different Sam 2000 ROM versions
- AIMsi Interface -> Fixed problem with V7 sending a zero when a PLU did not have a linked PLU
- AIMsi Interface -> Fixed problem with V7 sending the wrong linked PLU and M/M values for Casio 6600 when multiple levels were linked.
- AIMsi Interface -> If there are at least 50 items and any errors when updating SKUs from polling or creating SKUs from polling the PLU Tools menu disappears. This has been corrected.
- AIMsi Verify Setup -> now displays the dates of the AIMsi.exe, Ad.dll, and AIMsiDataTx.dll files
- Archive Agent -> Custom file archive; Changed directory select edit to modern version. Fixed issue where '\' was not being correctly added to end of path.
CASIO Changes:
- Casio 6100 -> Fixed an error with polling the PLU report when the Multi-Purpose area was selected.
- Casio 6100 -> Fixed an range check error when polling a PLU report when the "Range" option was used.
- Casio 6100 -> Removed a popup message when an error occurred during the shift PLU section of the PLU report; Instead the report will simply be marked as failed.
- Casio 6600 -> Added IPL 1.20.14 QSR
- Casio 6600 -> The Scan PLU Sale program now works.
- Casio 6600 -> Fixed editing script report options for Casio 6600 TCP/IP with an IRC and the previous registers to poll selections are individual registers, the settings are lost and only 'All' is enabled.
- Casio 6600/8500(IPL 1.4x)/7000(IPL 1.4x) -> The Scan PLU report now lists Stock.
Sam4s Changes:
- Sam4s -> Changed report options on all PLU Stock Eval reports to match the corresponding PLU Stock reports.
- Sam4s -> Save Alls now include Memory Allocations.
- Sam4s 1000/7000-> Fixed error with WLUs and Keyboard program.
- Sam4s 2000/5x0 -> Stock Eval report didn't work correctly if Price Levels as Cost option was disabled and a Price Level was set to Level 0. Fixed.
- Sam4s 2000-> Added Rom 3.00g30, including new function key defaults.
- Sam4s 2000-> Enhanced display of time keeping consolidation report
- Sam4s 52xx -> Added ROM 8.5
- Sam7000 Status Group -> fixed SQL error when updating AIMsi
Sharp Changes:
- Sharp 600 PLU -> modified the verify routine to exclude the PLU index field
- Sharp3500 -> fixed error in the department report
- Sharp530 -> fixed problem sending PLU Append and Changes only where the program was looking for a Sharp520 PLU table
TEC Changes:
- There were no TEC specific changes included in this release - the 'all' changes do apply to TEC registers.
More V7 Polling Software Advancements
V6 Polling Software Advancements
Inventory Advancements