Polling Software Advancements and Corrections by Build Number
V7 Build 180 (7.3.1.180) – December 9, 2010 - Full Release Version
General Changes:
- All -> The main tools menu is no longer replaced by local tools menus. Instead, those menus are labled indivdually. Ie. "PLU Tools"
- All -> The PLU Report Module has been entirely redone. It can now be accessed via Reports | Report Tools.
- All -> Area 6 is now an option for consolidate and advanced consoliate. (This is the Sam4s pre-poll reports area - only available on select reports.)
- Communications -> When the auto email fails for a report it writes to the log file that the email failed and sets the report status to successful
- Custom Consolidate -> Set up the ability to delete setup templates.
- Machine Maintenance - Disabled certain fields in the grid that should not be modified in the grid
- Mass Create -> modified so that the form is displayed in the center of the PLU form rather than the top left corner of monitor 1.
- QB Interface -> Fixed an issue when importing QB files with Assembly Items
- Security -> Added option to restrict which scripts a user could run.
- Security -> Added options to hide the program dropdown and the main tools menu.
- Security -> Fixed a few minor gliches in the setup area within Security.
- AIMsi Interface -> removed food stamp from the Casio 6600 Scan PLU tax status.
- AIMsi Interface -> set up deleting of PLU links records when PLU's are deleted from polling
- AIMsi Interface -> Set up updating all SKUs associated with a PLU Status Group change for the Sam4s 1000, 2000, 7000, and 520/530.
CASIO Changes:
- All Casios -> Changed the timing of RS232 communications to avoid timeouts if the computer could not process the data fast enough.
- Casio -> The Casio maintain areas that allow multiselecting now correctly clear all selected records when the clear button is clicked instead of only one.
- Casio 4500 Scan PLU -> changed the value of the scan code to 0 when creating a new scan Plu. If the value is 1, it can intefer with AIMsi.
- Casio 6600 -> Fixed an error sending multiple programs in a row over TCP/IP to an IRC when Broadcasting was turned on.
- Casio 6x00 -> Fixed error when the last block of a save was exactly 1 or 2 bytes
- Casio 6x00 -> Made adjustments to the timing on TCP/IP saves.
- Casio 7000/8500 -> Fixed sends of Bottle Link and Shift PLU files when certain fields were empty.
- Casio 7000/8500 1.4x -> Fixed the Verify on the Scan PLU form.
- Casio 8500 Scan PLU 140 -> removed extra communications menu on the top of the screen.
- Casio Registers -> Fixed timeouts occuring after a not allocated program was saved.
communication.
Sam4s Changes:
- Sam4s 2000/5x0 -> If the register is setup to use a price level as cost, the PLU Stock Evaluation Report will now use that cost field.
- Sam4s 28x -> Added Roms 1.028 and 1.032
- Sam4s 5200 -> The description of function keys could not be changed. Fixed.
- Sam4s 5200 -> The function key area had a phantom checkbox appear sometimes. Fixed.
- Sam4s 5x0 -> Added prepoll area as a pollable area. Note: This requires a special release code to access.
- Sam4s 5X0 -> Added ROM 1.00P
Sharp Changes:
- Sharp 3500 -> Added the EJ report
TEC Changes:
- Tec 1650 -> Fixed error when adding records to a PLU file. If the record added was not numerically the last PLU code, the regiser would not recoginize it's existence.
- TEC 1650 -> The FS model was not handling the Financial Items correctly. This has been corrected.
More V7 Polling Software Advancements
V6 Polling Software Advancements
Inventory Advancements